PROMETHEUS: Monitor and Disassembler Controls

ZX Land #06

PROMETHEUS

Monitor User Manual

Control keys:

Q - return to the assembler
M - set the disassembly address
CS+7 (UpCursor) - decrease the disassembly address by one
CS+6 (DownCursor) - increase the disassembly address by one
ENTER - enter data, or increase the disassembly address by one while
        simultaneously updating the main panel
CS+8 (RightCursor) - set a new disassembly address, saving the old one
                      in the address table (max. 10 addresses)
CS+5 (LeftCursor) - restore the previous disassembly address
CS+0 (Delete) - clear the screen
CS+2 (CapsLock) - clear the editor window without changing attributes
CS+1 (Edit) - exit the current option

Additional control keys in the 128 version:

CS+9 (Graphics) - set the disassembly address to the address contained
                  in the current instruction, saving the old one
SS+3 - cycle between hexadecimal and decimal number display modes
A - cycle through memory pages (banks 0, 1, 3, 4, 6, 7)
B - set the zero memory page and disable the bank-switching mechanism

Setting breakpoints and calling subroutines

SS+H - call a subroutine from the disassembly address
W - set the address from which the program will be called after a
    breakpoint is inserted
SS+U - insert a breakpoint at the disassembly address and call the
       program from the address set with the W key

IN/OUT operations

S - save a data block with the following parameters:
    First - start of block
    Last - end of block
    Leader - header type:
      a) a number from 0 to 255 - save the block without a header
      b) :xxx - save the block with a header named "xxx"

SS+S - a function similar to the previous one, differing only in that
       instead of the end of the block (Last), you specify the block
       length (Lenght)

J - load a data block into memory. Specify the parameters in the same
    way as for the save operation (S)

SS+J - load a data block into memory. When specifying the parameters,
       give its length instead of the end of the block

Y - load a block header and display its type:
    0 - BASIC
    1 - numeric array
    2 - character array
    3 - data block

When specifying block parameters, you can use labels (i.e. symbols)
from the symbol table. For example, if we want to save a program block
with a header, and its source text looks like this:

    org 60000
CLS ld  hl,16384
    ld  de,16385
    ld  bc,6143
    ld  (hl),l
    ldir
    ret
END $

then we can specify the block parameters as follows:

    First: CLS
    Last : END
    Leader: CLEAR

NOTE! In the 128 version, if you enter a name in response to the
header question (Leader), the data block will be saved to disk with
the extension "+.PCD". If you enter a number, the data block will be
saved to tape without a header.

To be continued.