| Refinement of Caller ID on the Z-80 | #
+-----------------------+ #
##########################
With all the undoubted conveniences of Caller ID on
Z-80 has a significant drawback:
with sharp fluctuations and voltage supply
The processor does not reset the mains supply -
is, as a result often on
electronic dialing key or sub-
When the handset is turned on, the logical level is supplied
coy 1, and the telephone line turns out
closed. And this, in turn, will entail
disabling the subscriber's telephone line on
PBX.
The described device (SEE FIGURE), made -
in the form of a prefix, allows you to resolve -
solve this problem. The principle of operation is -
rates are based on the following feature
Caller ID: if the finger processor fails -
no need to regenerate the display (this is
visible by appearing in the first digit
digits 8) and at the outputs of the decoder
K555IDH display pulses disappear. Because of
their absence is no longer reset
DD2 counter. To the counting input of the counter
pulses are received from the generator, assembled -
on elements DD1.1 and DD1.2.
After a whiletime depending on the capacitance
capacitor C2 resistance and resistance
side R2, at the output of element DD1.3 appears -
is the level of logical 0, which
resets the processor. Starts to work
display, and the DD2 counter is set to
initial state until the next failure.
The optimal counting time is 10 ... 15 s.
The set-top box microcircuits receive power from
Caller ID. Diode VD1 can be any silicon
vy, for example, the KDS21 or KD5OZ series.
Capacitors - KM, resistors - MLT-0.125.
Pins 12, 1З, and 14 of the DD1 microcircuit are as follows:
cannot be connected to each other. circuit board
with the details, the attachments are placed in their
free place inside the telephone set.