It might come in handy - About RESET.

╔════════════════════════ ═══════════════════ ═══════════════════╗
║  What if it comes in handy?       ║
╙─────────────────────────────── ───────────────────────────────╜
(C) EVP-SOFT

 Hello everyone.  I once came to one person to repair
vat Pentagon-128.  And at some stage I notice that his power
The businessman has already become a habit of pressing RESET when turning on the computer.
  Otherwise, there are different stripes on the screen. And this phenomenon is observed
many have. And the reason is simple - the electrolytic capacitor has dried out
in the reset circuit, or, if the computer has been heavily upgraded, then the capacitance
the existing capacitor simply may not be enough, and sometimes it’s just
In order to save money, it was not installed.
  This can be easily eliminated - you need to increase the nominal value of this condenser.
Satora. But don’t get carried away - if the denomination is too high,
For a few seconds after turning on or RESET, the computer will appear
network.  According to the GRM V.5 scheme, this is C5; according to the Pentagon-128 scheme (by SKS)
- this is C8;  By the way, 1OOuF is not enough for a sophisticated GRM, but
For a regular Pentagon, ZZmkF is enough.
  Well, the owner of that Pentagon apparently still presses RE-
SET - he has little idea of how ALZO7 and KTZ15 differ from
capacitor :)


Sincerely, Evgeniy aka EVP-SOFT


---IS-EDIT 6.06+
 *Origin:...money is usually not enough... (500:95/468)